3.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584394

RESUMO

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Resultado do Tratamento , Cardioversão Elétrica/efeitos adversos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
4.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584423

RESUMO

Electrical storm (ES) is a state of electrical instability, manifesting as recurrent ventricular arrhythmias (VAs) over a short period of time (three or more episodes of sustained VA within 24 h, separated by at least 5 min, requiring termination by an intervention). The clinical presentation can vary, but ES is usually a cardiac emergency. Electrical storm mainly affects patients with structural or primary electrical heart disease, often with an implantable cardioverter-defibrillator (ICD). Management of ES requires a multi-faceted approach and the involvement of multi-disciplinary teams, but despite advanced treatment and often invasive procedures, it is associated with high morbidity and mortality. With an ageing population, longer survival of heart failure patients, and an increasing number of patients with ICD, the incidence of ES is expected to increase. This European Heart Rhythm Association clinical consensus statement focuses on pathophysiology, clinical presentation, diagnostic evaluation, and acute and long-term management of patients presenting with ES or clustered VA.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Taquicardia Ventricular , Humanos , Fatores de Risco , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Incidência , Insuficiência Cardíaca/complicações , Ásia/epidemiologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/complicações
5.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38587017

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , América Latina , Resultado do Tratamento , Cateteres , Ásia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
6.
Heart Rhythm ; 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38641221

RESUMO

BACKGROUND: Premature ventricular contractions (PVCs) burden is a risk factor for heart failure and cardiovascular death in patients with structural heart disease. Long-term ECG monitoring can have a significant impact on PVC burden evaluation by further defining PVC distribution patterns. OBJECTIVE: This study aimed to ascertain the optimal duration of ECG monitoring to characterize PVC burden and understand clinical characteristics associated with frequent PVCs and NSVT in a large US cohort. METHODS: Commercial data (iRhythm's Zio patch) from June 2011 to April 2022 were analyzed. Inclusion criteria were age >18 years, PVC burden ≥5%, and wear period ≥13 days. PVC burden cutoffs were determined based on AHA/ACC/HRS guidelines for very frequent PVCs (10,000-20,000 over 24 hours). Patients were categorized by PVC densities : Low (<10%), Moderate (10% to <20%) and High (≥20%). Mean measured error was assessed at baseline and daily until wear period's end for overall PVC Burden and different PVC densities. RESULTS: Analysis of 106,705 patch monitors revealed a study population with mean age of 70.6±14.6 years; 33.6% female. PVC burden was higher in males and those >65 years of age. PVC burden mean error decreased from 2.9% at 24 hours to 1.3% at 7 days, and 0.7% at 10 days. Number of VT episodes per patient increased with increasing PVC burden (p<0.0001). CONCLUSION: Extending ambulatory monitoring beyond 24 hours to 7 days or more, improves accuracy of assessing PVC burden. VT frequency and duration vary based on initial PVC density, highlighting the need for prolonged cardiac monitoring.

7.
Artigo em Inglês | MEDLINE | ID: mdl-38609733

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society (HRS), the Asia Pacific HRS, and the Latin American HRS.

8.
Circ Arrhythm Electrophysiol ; 17(4): e012717, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38390748

RESUMO

BACKGROUND: The effect of contact force (CF) on lesion formation is not clear during pulsed field ablation (PFA). The aim of this study was to evaluate the impact of CF, PFA, and their interplay through the PFA index (PF index) formula on the ventricular lesion size in swine. METHODS: PFA was delivered through the CF-sensing OMNYPULSE catheter. Predefined PFA applications (×3, ×6, ×9, and ×12) were delivered maintaining low (5-25 g), high (26-50 g), and very high (51-80 g) CFs. First, PFA lesions were evaluated on necropsy in 11 swine to investigate the impact of CF/PFA-and their integration in the PF index equation-on lesion size (study characterization). Then, 3 different PF index thresholds-300, 450, and 600-were tested in 6 swine to appraise the PF index accuracy to predict the ventricular lesion depth (study validation). RESULTS: In the study characterization data set, 111 PFA lesions were analyzed. CF was 32±17 g. The average lesion depth and width were 3.5±1.2 and 12.0±3.5 mm, respectively. More than CF and PFA dose alone, it was their combined effect to impact lesion depth through an asymptotically increasing relationship. Likewise, not only was the PF index related to lesion depth in the study validation data set (r2=0.66; P<0.001) but it also provided a prediction accuracy of the observed depth of ±2 mm in 69/73 lesions (95%). CONCLUSIONS: CF and PFA applications play a key role in lesion formation during PFA. Further studies are required to evaluate the best PFA ablation settings to achieve transmural lesions.


Assuntos
Ablação por Cateter , Suínos , Animais , Ablação por Cateter/efeitos adversos , Ventrículos do Coração/cirurgia , Cateteres , Desenho de Equipamento
9.
JACC Clin Electrophysiol ; 10(4): 709-715, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38310489

RESUMO

BACKGROUND: High-voltage pulses can cause hemolysis. OBJECTIVES: The authors evaluated the occurrence of hemoglobinuria after pulsed-field ablation (PFA) and its impact on renal function in patients with atrial fibrillation (AF). METHODS: A consecutive series of patients with AF undergoing PFA were included in this analysis. The initial patients who did not receive postablation hydration immediately after the procedure were classified as group 1 (n = 28), and the rest of the study patients who received planned fluid infusion (0.9% sodium chloride ≥2 L) after the procedure were categorized as group 2 (n = 75). RESULTS: Of the 28 patients in group 1, 21 (75%) experienced hemoglobinuria during the 24 hours after catheter ablation. The mean postablation serum creatinine (S-Cr) was significantly higher than the baseline value in those 21 patients (1.46 ± 0.28 mg/dL vs 0.86 ± 0.24 mg/dL, P < 0.001). Of those 21 patients, 4 (19%) had S-Cr. >2.5 mg/dL (mean: 2.95 ± 0.21 mg/dL). The mean number of PF applications was significantly higher in those 4 patients than in the other 17 patients experiencing hemoglobinuria (94.63 ± 3.20 vs 46.75 ± 9.10, P < 0.001). In group 2 patients, no significant changes in S-Cr were noted. The group 2 patients received significantly higher amounts of fluid infusion after catheter ablation than did those in group 1 (2,082.50 ± 258.08 mL vs 494.01 ± 71.65 mL, P < 0.001). In multivariable analysis, both hydration (R2 = 0.63, P < 0.01) and number of PFA applications (R2 = 0.33, P < 0.01) were independent predictors of postprocedure acute kidney injury. CONCLUSIONS: On the basis of our findings, both the number of PFA applications and postablation hydration were independent predictors of renal insult that could be prevented using planned fluid infusion immediately after the procedure.


Assuntos
Injúria Renal Aguda , Fibrilação Atrial , Ablação por Cateter , Hemoglobinúria , Humanos , Fibrilação Atrial/cirurgia , Masculino , Feminino , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Pessoa de Meia-Idade , Injúria Renal Aguda/prevenção & controle , Injúria Renal Aguda/etiologia , Idoso , Hemoglobinúria/etiologia , Hemoglobinúria/prevenção & controle , Creatinina/sangue , Estudos Retrospectivos , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Hidratação/métodos
10.
Front Cardiovasc Med ; 11: 1343424, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38322767

RESUMO

Introduction: Implantable cardiac monitors (ICMs) provide long-term arrhythmia monitoring, but high rates of false detections increase the review burden. The new "SmartECG" algorithm filters false detections. Using large real-world data sets, we aimed to quantify the reduction in workload and any loss in sensitivity from this new algorithm. Methods: Patients with a BioMonitor IIIm and any device indication were included from three clinical projects. All subcutaneous ECGs (sECGs) transmitted via remote monitoring were classified by the algorithm as "true" or "false." We quantified the relative reduction in workload assuming "false" sECGs were ignored. The remote monitoring workload from five hospitals with established remote monitoring routines was evaluated. Loss in sensitivity was estimated by testing a sample of 2000 sECGs against a clinical board of three physicians. Results: Of our population of 368 patients, 42% had an indication for syncope or pre-syncope and 31% for cryptogenic stroke. Within 418.5 patient-years of follow-up, 143,096 remote monitoring transmissions contained 61,517 sECGs. SmartECG filtered 42.8% of all sECGs as "false," reducing the number per patient-year from 147 to 84. In five hospitals, nine trained reviewers inspected on average 105 sECGs per working hour. This results in an annual working time per patient of 83 min without SmartECG, and 48 min with SmartECG. The loss of sensitivity is estimated as 2.6%. In the majority of cases where true arrhythmias were rejected, SmartECG classified the same type of arrhythmia as "true" before or within 3 days of the falsely rejected sECG. Conclusion: SmartECG increases efficiency in long-term arrhythmia monitoring using ICMs. The reduction of workload by SmartECG is meaningful and the risk of missing a relevant arrhythmia due to incorrect filtering by the algorithm is limited.

11.
Int J Cardiol ; 400: 131807, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38272130

RESUMO

BACKGROUND: Left ventricular assist devices (LVADs) are an increasingly used strategy for the management of patients with advanced heart failure (HF). Subcutaneous implantable cardioverter defibrillator (S-ICD) might be a viable alternative to conventional ICDs with a lower risk of short- and long-term of device-related complications and infections.The aim of this multicenter study was to evaluate the outcomes and management of S-ICD recipients who underwent LVAD implantation. METHODS: The study population included patients with a preexisting S-ICD who underwent LVAD implantation for advanced HF despite optimal medical therapy. RESULTS: The study population included 30 patients (25 male; median age 45 [38-52] years).The HeartMate III was the most common LVAD type. Median follow-up in the setting of concomitant use of S-ICDs and LVADs was 7 months (1-20).There were no reports of inability to interrogate S-ICD systems in this population. Electromagnetic interference (EMI) occurred in 21 (70%) patients. The primary sensing vector was the one most significantly involved in determining EMI. Twenty-seven patients (90%) remained eligible for S-ICD implantation with at least one optimal sensing vector. The remaining 3 patients (10%) were ineligible for S-ICD after attempts of reprogramming of sensing vectors. Six patients (20%) experienced inappropriate shocks (IS) due to EMI. Six patients (20%) experienced appropriate shocks. No S-ICD extraction because of need for antitachycardia pacing, ineffective therapy or infection was reported. CONCLUSIONS: Concomitant use of LVAD and S-ICD is feasible in most patients. However, the potential risk of EMI oversensing, IS and undersensing in the post-operative period following LVAD implantation should be considered. Careful screening for EMI should be performed in all sensing vectors after LVAD implantation.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Coração Auxiliar , Marca-Passo Artificial , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/complicações , Coração Auxiliar/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Resultado do Tratamento
12.
Card Electrophysiol Clin ; 16(1): ix, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38280818
13.
Heart Rhythm ; 21(4): 410-418, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38246594

RESUMO

BACKGROUND: Outcome comparisons among subcutaneous implantable cardioverter-defibrillator (S-ICD) recipients with nonischemic cardiomyopathies are scarce. OBJECTIVE: The aim of this study was to evaluate differences in device-related outcomes among S-ICD recipients with different structural substrates. METHODS: Patients enrolled in the i-SUSI (International SUbcutaneouS Implantable cardioverter defibrillator registry) project were grouped according to the underlying substrate (ischemic vs nonischemic) and subgrouped into dilated cardiomyopathy, hypertrophic cardiomyopathy, Brugada syndrome (BrS), arrhythmogenic right ventricular cardiomyopathy (ARVC). The main outcome of our study was to compare the rates of appropriate and inappropriate shocks and device-related complications. RESULTS: Among 1698 patients, the most common underlying substrate was ischemic (31.7%), followed by dilated cardiomyopathy (20.5%), BrS (10.8%), hypertrophic cardiomyopathy (8.5%), and ARVC (4.4%). S-ICD for primary prevention was more common in the nonischemic cohort (70.9% vs 65.4%; P = .037). Over a median (interquartile range) follow-up of 26.5 (12.6-42.8) months, no differences were observed in appropriate shocks between ischemic and nonischemic patients (4.8%/y vs 3.9%/y; log-rank, P = .282). ARVC (9.0%/y; hazard ratio [HR] 2.492; P = .001) and BrS (1.8%/y; HR 0.396; P = .008) constituted the groups with the highest and lowest rates of appropriate shocks, respectively. Device-related complications did not differ between groups (ischemic: 6.4%/y vs nonischemic: 6.1%/y; log-rank, P = .666), nor among underlying substrates (log-rank, P = .089). Nonischemic patients experienced higher rates of inappropriate shocks than did ischemic S-ICD recipients (4.4%/y vs 3.0%/y; log-rank, P = .043), with patients with ARVC (9.9%/y; P = .001) having the highest risk, even after controlling for confounders (adjusted HR 2.243; confidence interval 1.338-4.267; P = .002). CONCLUSION: Most S-ICD recipients were primary prevention nonischemic cardiomyopathy patients. Among those, patients with ARVC tend to receive the most frequent appropriate and inappropriate shocks and patients with BrS the least frequent appropriate shocks.


Assuntos
Displasia Arritmogênica Ventricular Direita , Cardiomiopatias , Cardiomiopatia Dilatada , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Cardioversão Elétrica/efeitos adversos , Displasia Arritmogênica Ventricular Direita/complicações , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/terapia , Sistema de Registros , Resultado do Tratamento
14.
J Am Coll Cardiol ; 83(1): 82-108, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38171713

RESUMO

Electrophysiological and interventional procedures have been increasingly used to reduce morbidity and mortality in patients experiencing cardiovascular diseases. Although antithrombotic therapies are critical to reduce the risk of stroke or other thromboembolic events, they can nonetheless increase the bleeding hazard. This is even more true in an aging population undergoing cardiac procedures in which the combination of oral anticoagulants and antiplatelet therapies would further increase the hemorrhagic risk. Hence, the timing, dose, and combination of antithrombotic therapies should be carefully chosen in each case. However, the maze of society guidelines and consensus documents published so far have progressively led to a hazier scenario in this setting. Aim of this review is to provide-in a single document-a quick, evidenced-based practical summary of the antithrombotic approaches used in different cardiac electrophysiology and interventional procedures to guide the busy clinician and the cardiac proceduralist in their everyday practice.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Idoso , Fibrinolíticos/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Anticoagulantes/efeitos adversos , Hemorragia/induzido quimicamente , Acidente Vascular Cerebral/tratamento farmacológico , Resultado do Tratamento
15.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38266130

RESUMO

AIMS: Different disease processes can combine to cause atrial fibrillation (AF). Their contribution to recurrent AF after ablation in patients is not known. Cardiovascular processes associated with recurrent AF after AF ablation were determined by quantifying biomolecules related to inflammation, metabolism, proliferation, fibrosis, shear stress, atrial pressure, and others in the AXAFA biomolecule study. METHODS AND RESULTS: Twelve circulating cardiovascular biomolecules (ANGPT2, BMP10, CA125, hsCRP, ESM1, FABP3, FGF23, GDF15, IGFBP7, IL6, NT-proBNP, and hsTnT) were quantified in plasma samples obtained prior to a first AF ablation using high-throughput, high-precision assays. Cox regression was used to identify biomolecules associated with recurrent AF during the first 3 months after AF ablation. In 433 patients (64 years [58, 70]; 33% women), baseline concentrations of ANGPT2, BMP10, hsCRP, FGF23, FABP3, GDF15, and NT-proBNP were elevated in patients with recurrent AF (120/433; 28%). After adjustment for 11 clinical features and randomized treatment, elevated NT-proBNP [hazard ratio (HR) 1.58, 95% confidence interval (1.29, 1.94)], ANGPT2 [HR 1.37, (1.12, 1.67)], and BMP10 [HR 1.24 (1.02, 1.51)] remained associated with recurrent AF. Concentrations of ANGPT2, BMP10, and NT-proBNP decreased in patients who remained arrhythmia free, but not in patients with recurrent AF, highlighting their connection to AF. The other eight biomarkers showed unchanged concentrations. CONCLUSION: Elevated concentrations of ANGPT2, BMP10, and NT-proBNP are associated with recurrent AF after a first AF ablation, suggesting that processes linked to disturbed cardiomyocyte metabolism, altered atrial shear stress, and increased load contribute to AF after AF ablation in patients.


Assuntos
Fibrilação Atrial , Humanos , Feminino , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Proteína C-Reativa , Átrios do Coração , Peptídeo Natriurético Encefálico , Biomarcadores , Modelos de Riscos Proporcionais , Fragmentos de Peptídeos , Proteínas Morfogenéticas Ósseas
16.
Heart Rhythm ; 2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38246567

RESUMO

BACKGROUND: Long-term oral anticoagulation is the mainstay therapy for thromboembolic (TE) prevention in patients with atrial fibrillation. However, left atrial appendage occlusion (LAAO) could be a safe alternative to direct oral anticoagulants (DOACs) in patients with a very high TE risk profile. OBJECTIVE: The purpose of this study was to compare the safety and efficacy of LAAO vs DOACs in patients with atrial fibrillation at very high stroke risk (CHA2DS2-VASc [congestive heart failure, hypertension, age ≥ 75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65-74 years, sex category] score ≥ 5). METHODS: Data from patients with CHA2DS2-VASc score ≥ 5 were extracted from a prospective multicenter database. To attenuate the imbalance in covariates between groups, propensity score matching was used (covariates: CHA2DS2-VASc and HAS-BLED [hypertension, abnormal renal or liver function, stroke, bleeding, labile international normalized ratio, elderly, drugs or alcohol] scores), which resulted in a matched population of 277 patients per group. The primary end point was a composite of cardiovascular death, TE events, and clinically relevant bleeding during follow-up. RESULTS: Of 2381 patients, 554 very high risk patients were included in the study (mean age 79 ± 7 years; CHA2DS2-VASc score 5.8 ± 0.9; HAS-BLED score 3.0 ± 0.9). The mean follow-up duration was 25 ± 11 months. A higher incidence of the composite end point was documented with DOACs compared with LAAO (14.9 events per 100 patient-years in the DOAC group vs 9.4 events per 100 patient-years in the LAAO group; P = .03). The annualized clinically relevant bleeding risk was higher with DOACs (6.3% vs 3.2%; P = .04), while the risk of TE events was not different between groups (4.1% vs 3.2%; P = .63). CONCLUSION: In high-risk patients, LAAO had a similar stroke prevention efficacy but a significantly lower risk of clinically relevant bleeding when compared with DOACs. The clinical benefit of LAAO became significant after 18 months of follow-up.

18.
Pacing Clin Electrophysiol ; 47(2): 185-194, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38010836

RESUMO

BACKGROUND: Despite its clinical benefits, patient compliance to remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) varies and remains under-studied in diverse populations. OBJECTIVE: We sought to evaluate RM compliance, clinical outcomes, and identify demographic and socioeconomic factors affecting RM in a diverse urban population in New York. METHODS: This retrospective cohort study included patients enrolled in CIED RM at Montefiore Medical Center between December 2017 and May 2022. RM compliance was defined as the percentage of days compliant to RM transmission divided by the total prescribed days of RM. Patients were censored when they were lost to follow-up or at the time of death. The cohorts were categorized into low (≤30%), intermediate (31-69%), and high (≥70%) RM compliance groups. Statistical analyses were conducted accordingly. RESULTS: Among 853 patients, median RM compliance was 55%. Age inversely affected compliance (p < .001), and high compliance was associated with guideline-directed medical therapy (GDMT) usage and implantable cardioverter defibrillator (ICD)/cardiac resynchronization defibrillator (CRTD) devices. The low-compliance group had a higher mortality rate and fewer regular clinic visits (p < .001) than high-compliance group. Socioeconomic factors did not significantly impact compliance, while Asians showed higher compliance compared with Whites (OR 3.67; 95% CI 1.08-12.43; p = .04). Technical issues were the main reason for non-compliance. CONCLUSION: We observed suboptimal compliance to RM, which occurred most frequently in older patients. Clinic visit compliance, optimal medical therapy, and lower mortality were associated with higher compliance, whereas insufficient understanding of RM usage was the chief barrier to compliance.


Assuntos
Desfibriladores Implantáveis , Tecnologia de Sensoriamento Remoto , Humanos , Idoso , Estudos Retrospectivos , Dispositivos de Terapia de Ressincronização Cardíaca , Demografia
19.
Artigo em Inglês | MEDLINE | ID: mdl-38069973

RESUMO

BACKGROUND: Studies have reported development of pulmonary hypertension (PH) secondary to reduced LA compliance following AF ablation. OBJECTIVES: We aimed to compare the risk of worsening of baseline PH between non-paroxysmal AF patients undergoing pulsed-field ablation (PFA) and standard radiofrequency ablation (RFA). METHODS: This multicenter study included 28 nonparoxysmal AF patients with PH undergoing a PFA-based ablation procedure after >1 failed RFA. A cohort of 28 AF patients with PH, scheduled for repeat RFA, 1:1 propensity-score matched using a multivariable logistic model, were used as the comparator group. Right heart catheterization and echocardiography were performed before and after the procedure to assess the pulmonary artery pressure (PAP). PH was defined as resting mean PAP of >20 mm Hg. RESULTS: The baseline characteristics of the PFA and propensity-matched RFA groups were comparable. The mean PAP assessments at baseline, follow-up, and change from baseline were analyzed. The groups had comparable baseline mean pulmonary artery pressures (mPAP) (P = 0.177). After adjustment for baseline mPAP in an analysis of covariance model, the least-squares means change at 3 months after ablation was -1.71 ± 1.03 mm Hg and 19.67 ± 1.03 mm Hg in PFA and RFA, respectively (P <0.001). CONCLUSIONS: In this propensity-matched population, no worsening of mPAP was detected following pulsed-field ablation in patients with pre-existing PH undergoing a repeat procedure for recurrence.

20.
J Cardiovasc Electrophysiol ; 34(12): 2621-2625, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37987539

RESUMO

INTRODUCTION: Catheter ablation of atrial fibrillation (AF) has emerged as the most effective therapy. However, rare anatomical abnormalities such as situs inversus totalis, dextrocardia, or interrupted inferior vena cava can make ablation challenging. METHODS AND RESULTS: We report a case of a 55-year-old woman with situs inversus totalis, dextrocardia, surgical atrial septal defect repair, left-sided dual chamber pacemaker in place, and symptomatic recurrent persistent AF who underwent successful pulmonary vein and posterior wall isolation by the superior access from the left internal jugular vein. CONCLUSIONS: It is a feasible and safe approach with support of transesophageal echocardiography and multiple emerging technologies.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Dextrocardia , Cardiopatias Congênitas , Situs Inversus , Feminino , Humanos , Pessoa de Meia-Idade , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/diagnóstico por imagem , Situs Inversus/complicações , Situs Inversus/diagnóstico por imagem , Situs Inversus/cirurgia , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/cirurgia , Dextrocardia/complicações , Dextrocardia/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia
SELEÇÃO DE REFERÊNCIAS